Up | Down | Top | Bottom


Concord Screen

Concord Wedge-Wire Screens

Concord Screen The continuous wedge-shaped slots in the element effectively separates the solids from the fluid passing through the unit. The unique Concord Screen wedge design of the element offers high strength, high open area and less clogging than other types of elements. These 316 stainless steel screen are available in slot sizes from 0.001" to 0.187".

Fabric

Concord Screen fabric media are woven from synthetic fibers and are chemically compatible with most liquids. Fabric media offers an excellent means of filtering liquids with retention levels down to nominal 5 microns. These synthetic fibers also have excellent solids release characteristics for easy cleaning.


Concord Screen Wire Mesh

Woven wire mesh screens provide good solids release characteristic. The wire mesh screens are made of Type 316 stainless steel and wedge-wire inner backing is used in order to give it support. Wire mesh sizes are available from 1 micron to 150 mesh.

Specifications

HOUSING MATERIAL:
Carbon steel or 316 stainless steel
GASKETS:
Buna N, Ethylene Propylene, (EPR), Viton, Silicone or Teflon
FILTER MEDIA:
Concord Screen Stainless steel, polyester or polypropylene
DESIGN PRESSURE:
150 psi and 300 psi standard construction
TEMPERATURE LIMITS:
Temperature limits will vary depending on the gasket and screen material
FLOW RATE:
Maximum flow rate per element is 150 GPM




Example:

Concord Screen Determine filter size for 500 gpm using wedge-wire element with 0.006" slot.
  1. From Table 1 determine the sizing factor (which is 2.1).
  2. Multiply the flow by the sizing factor to give us the factored flow (ie. 500 x 2.1 = 1,050 factored flow).
  3. From Chart 1 determine the number of elements needed. In our example for factored flow of 1,050, the number of elements needed is 5.
  4. Table 2 gives the Model No. needed for either internal or external backwashing units.
  5. Make sure that maximum flow rate per element is not exceeded. Divide the flow rate by the number of elements. The result should not exceed 100 gpm (500 / 5 = 100 gpm).

Concord Screen
* Above sizing factor is based on filtering water

Concord Screen
Units placed back-to-back are half the length "L"
Up | Down | Top | Bottom